Seiko STOPWATCH S143 Guide de dépannage Page 6

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 14
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 5
SPLIT
RECALL
BLOCK
LAP
STOP
BATT.
LAP
F
E
(Reset)
SPLIT
RECALL
BLOCK
LAP
STOP
BATT.
LAP
F
E
(Reset)
SPLIT
RECALL
BLOCK
LAP
STOP
BATT.
LAP
F
E
(Start data)
SPLIT
RECALL
BLOCK
LAP
STOP
BATT.
LAP
F
E
(Fastest lap time display)
SPLIT
RECALL
BLOCK
LAP
STOP
BATT.
LAP
F
E
(Lap/split data in block "1")
SPLIT
RECALL
BLOCK
LAP
STOP
BATT.
LAP
F
E
(Stop)
Start time
Stop time 
2:11'17"99
Lap/split no.8
split time 2:1'14"12
lap time  16'42"33
Fastest lap no.
Lap/split no.
split time
Fastest LAP
Stop time
Recall
button
Recall button Recall button
Recall button
Recall
button
Recall
button
Recall
button
Recall button
Start date
The fastest lap time in this block
is displayed together with the lap
number.
BLOCK2
Start data
BLOCK3
Start data
BLOCK3
Stop time
Data in block "1"
When the stopwatch is reset or stopped:
The data is recalled starting from the first data in block "1".
<Ex.) When the display is reset to "00" in block "4">
When the stopwatch is measuring:
The data is recalled starting from the newest one.
〈ex.) When the measurement of the third lap / split time in block "4" has been completed.〉
SPLIT
RECALL
BLOCK
LAP
STOP
BATT.
LAP
F
E
BLOCK3
Start data
BLOCK3
Fastest lap
BLOCK3
Stop time
BLOCK4
Lap/split time 3
BLOCK4
Lap/split time 3
BLOCK1
Lap/split time 1
Lap/split time 3 Lap/split time 2 Lap/split time 1
Data in block "4"
The colon (:) starts flashing.
Fastest lap no.
(Display of the fastest lap time in block "4")
When the stopwatch is mesuring, the measurement in progress is shown in the bottom row of the display.
Recall buttonRecall button Recall button Recall button
Recall button
Recall buttonRecall buttonRecall
button
Recall
button
■How to clear the stored data (All clear of
data)
・The memory clear function is useful in
the following cases.
a)When the stored data becomes
unnecessary.
b)When the residual memory is not
sufficient for a new measurement.
・Once the following steps are taken to
clear the data, all the stored data is
erased from memory. The stored data
cannot be erased one by one or block by
block.
While the stopwatch is measuring or
when the digits are not reset after the
end of the measurement, the stored data
cannot be erased from memory.
In that case, end the measurement and
reset the stopwatch.
Press recall button
In the memory recall display, the stored
data can be erased irrespective of which
data is displayed.
SPLIT
RECALL
BLOCK
LAP
STOP
BATT.
LAP
F
E
(Digits reset to "00")
SPLIT
RECALL
BLOCK
LAP
STOP
BATT.
LAP
F
E
(Start data)
Recall button
SPLIT
RECALL
BLOCK
LAP
STOP
BATT.
LAP
F
E
(Memory clear procedure)
Button ○
B
SPLIT
RECALL
BLOCK
LAP
STOP
BATT.
LAP
F
E
(Digits reset to "00")
Keep button ○
B
pressed for more than 1.5 seconds.
While button ○
B
is kept pressed, the display below is shown with warning beeps.
After 1.5 seconds, the stored data is erased from memory with a long beep.
All the data is erased from memory and the initial measurement display is shown.
Unless button ○
B
is kept pressed for more than 1.5 seconds, the stored data will not be erased from
memory.
Vue de la page 5
1 2 3 4 5 6 7 8 9 10 11 12 13 14

Commentaires sur ces manuels

Pas de commentaire