DIP-Switch Functions
Table 3-2. DIP-switch Functions
DIP SW
ON
OFF
SW-1
SW-2
Ignores data reception errors
Prints “?” for data reception errors
Data buffer 45 bytes
Data buffer 4 Kbytes
SW-3
SW-4
XON/XOFF control
With parity
DSR/DTR control
without parity
Odd parity
SW-5
Even parity
SW-6
SW-7
SW-8
SW-9
Change baud rate (Refer to Table 3-3)
Change print density (Refer to Table 34)
SW-10
Thermal label paper
Thermal paper
Table 3-3. Baud Rate Selection
Baud Rate SW 1-6 SW 1-7
1200 bps ON ON
4800
OFF ON
9600
ON
OFF
19200
OFF
OFF
Table 3-4. Print Density Selection
Print Density SW 1-8 SW 1-9 Level
LIGHT
ON ON
1
I
OFF OFF 2
I
I
ON
OFF 3
DARK
OFF ON
4
13