3-30
(13) FRONT HEATER T
Set the front heater temperature. However,
when “**” is set, the front heater does not work.
<Parameter (numeral input)>
15˚C to 55˚C Centigrade temperature setting range
59˚F to 131˚F Fahrenheit temperature setting range
(14) PRINT HEATER T
Set the print heater temperature. However,
when “**” is set, the print heater does not work.
<Parameter (numeral input)>
15˚C to 55˚C Centigrade temperature setting range
59˚F to 131˚F Fahrenheit temperature setting range
(15) REAR HEATER T
Set the rear heater temperature. However,
when “**” is set, the rear heater does not work.
<Parameter (numeral input)>
15˚C to 55˚C Centigrade temperature setting range
59˚F to 131˚F Fahrenheit temperature setting range
- Switching the display between Centigrade temperature and Fahrenheit temperature is
performed with (4) Temperature Unit in SETUP MENU. ( P.3-55)
Centigrade/Fahrenheit conversion formula
F=(9/5)C+32
C=(5/9)(F-32)
#FRONT HEATER T
>XX:30˚C
(When temperature unit is Centigrade)
#FRONT HEATER T
>XX:086˚F
(When temperature unit is Fahrenheit)
#PRINT HEATER T
>XX:30˚C
(When temperature unit is Centigrade)
#PRINT HEATER T
>XX:086˚F
(When temperature unit is Fahrenheit)
#REAR HEATER T
>XX:30˚C
(When temperature unit is Centigrade)
#REAR HEATER T
>XX:086˚F
(When temperature unit is Fahrenheit)