3 -2 Adjusting the Paper-End Detector
n
The paper-end detector
The paper-end detector senses when the paper is nearing its end and
turns on the PAPER lamp.
The paper-end detector can be adjusted according the thickness of the
Paper.
n
How to adjust the paper-end detector
Roll paper may differ in spool size, so it may be necessary to adjust
the paper-end detector.
Use the specified paper roll with
a cure
inside diameter (d1) of 12mm
and an outside diameter (d2) of 18 mm.
The thickness of the spool can vary; use the table to determine
the paper-end detector adjustment.
Table 3-l. Adjustment Values of the Paper-end Detector
Adjustment Value Dimension of T (mm)
#l
Approx. 0
----------------------------------------------
#2
Approx. 2
.---------------------------------------------
#3
Approx. 4
---------------------------------------------
#4
Approx. 6
----------------------------------------------
#5
Approx. 8
----------------------------------------------
#6
Approx . 10
d2
-12-